EI 900 SERIES
EI 900 W/O smart card Readers are stylish as well as functional. Can be mounted directly on a Wall or Panel. It is a Mifare® Contactless Smart Card Reader designed with the practical site installation requirements in mind.
The Reader can respond to both Mifare and Desfire cards simultaneously, thus eliminating the need for config cards.
The mullion shape allows easy installation on door architraves where many readers will not fit.
It is a Wiegand cum RS485 Interface Reader. We can integrate it to any door controller provided the details of the Wiegand bit pattern are made available or the Door Controller RS485 interface conforms to OSDP Protocol. Since it is manufactured totally in house, customizations are possible.
The reader can communicate with the controller either on the Wiegand or OSDP interface. This can be achieved by changing the DIP switch settings before powering on the Reader.
- Conforms to ISO 14443A (Type 1, 2, 3 & 4) (13.56 MHz)
- Fast verification and authentication processing time; less than one second.
- Visual (LED) and audible (Buzzer) feedback
- Any door controller can be integrated
- It has a slim profile which is attractive on the panel
- Weigand Interface
- RS 485 OSDP
- Manufactured in India
Power Requirement | 12—14 V DC |
Output Interface | Weigand 26 to 100 bit pattern as per customer specification |
Operating Current Consumption | 90 ma |
Communication | Weigand and RS 485 - OSDP |
Node id | DIP switch settings 1 & 2 are used to set the Node Id |
Baud Rate | DIP switch setting 3 is used to set the Baud Rate |
Communication Interface | DIP switch setting 4 is used to set for Wiegand or OSDP |
Light Indication | Green & Red |
Smart Cards | ISO14443A (Type 1,2,3 & 4), Mifare & Desfire EV2 |
Reader Frequency | 13.56 MHz |
Read Range | 3 to 4 CM |
Operating Temperature | 0º C to 55º Centigrade |
Relative Humidity | 90% Max, operating Non condensing |
Size | 140mm * 45mm * 32mm |
Weight | 160 gms ( approximately ) |
Colour | Black Top & Army Green bottom |
Warranty Policy | 1 year for defective workmanship |